University of North Florida
Browse the Citations
-OR-

Contact Info

Stuart Chalk, Ph.D.
Department of Chemistry
University of North Florida
Phone: 1-904-620-1938
Fax: 1-904-620-3535
Email: schalk@unf.edu
Website: @unf

View Stuart Chalk's profile on LinkedIn

Plant

Classification: Plant -> kelp

Citations 3

"Determination Of Iodate By Flow Injection Analysis With 5-Br-PADAP [2-(5-bromo-2-pyridylazo)-5-diethylamino-o-phenol] And Thiocyanate"
Microchim. Acta 1991 Volume 103, Issue 5-6 Pages 279-283
Xingguo Chen, Xinwei Zhao, Zongyan Kou and Zhide Hu

Abstract: Sample (100 µL) was merged with 0.01 M KSCN solution and 0.4 mM 5-Br-PADAP ethanolic solution in 1.2 M H2SO4 (both at 0.8 mL min-1). After reaction the red-violet triatomic ion associate formed was measured at 550 nm. Beer's law was obeyed from 2 to 20 µM-IO-3. The method was applied to the analysis of kelp. The detection limit was 0.6 µM and recovery was >97%. Sample throughput was 84 h-1; BrO3- and IO4- interfered.
Iodate Spectrophotometry Interferences

"Spectrophotometric Determination Of Trace Iodide By Flow Injection Analysis"
Fenxi Huaxue 1996 Volume 24, Issue 6 Pages 720-723
Wang, P.;Shi, S.J.

Abstract: Portions of standard iodide (I) solution were injected into a flow injection analyzer. (schematic shown) and treated with a mixture of 1% bromine and 2% H3PO4 in water in a reaction coil (5 cm x 0.7 mm i.d.). The mixed solution was treated with aqueous 6% sulfosalicylic acid in a second coil (94 cm x 0.7 mm i.d.) and the absorbance of the colored product formed was measured at 580 nm. The calibration graph was linear up to 1 mg/l I. The RSD was 3.3%. Sampling frequency was 80 runs per h. There was little interference. The method was applied to the analysis of iodine-containing tablets, table salt, animal feed and kelp, with recovery of 90-97.5%.
Iodide Spectrophotometry Interferences

"Design And Application Of A Micro-versatile Phase Separator For Continuous Liquid-liquid Extraction. 2. Analytical Performance Of Flow Injection Solvent Extraction Spectrophotometry For The Determination Of Iodide"
Yankuang Ceshi 1998 Volume 17, Issue 1 Pages 29-32
Lin Shoulin, Zheng Qunxiong

Abstract: A glass gravity separator for continuous liq.-liq. extraction system was developed and used for the determination of trace iodide ion by online extraction-spectrophotometry. The separator provides several advantages over the existing ones reported in the literatures. The flow ratio of aqueous mobile phase to organic mobile phase (.upsilon.aq:.upsilon.org) is 30. The linear range for I- is 0-3.000 mg/L with detection limit of 70 µg/L. A precision of 2.2% relative standard deviation (1 mg/L of I-, .eta.=7) and a sample throughput of 25/h were obtained. The method was applied to the determination of I- in kelp with standard addition recovery of 98%.
Iodide Spectrophotometry Solvent extraction Apparatus Phase separator Standard additions calibration