University of North Florida
Browse the Citations
-OR-

Contact Info

Stuart Chalk, Ph.D.
Department of Chemistry
University of North Florida
Phone: 1-904-620-1938
Fax: 1-904-620-3535
Email: schalk@unf.edu
Website: @unf

View Stuart Chalk's profile on LinkedIn

Ouabain

  • IUPAC Name: 3-[(1R,3S,5S,8R,9S,10R,11R,13R,14S,17R)-1,5,11,14-tetrahydroxy-10-(hydroxymethyl)-13-methyl-3-[(2R,3R,4R,5R,6S)-3,4,5-trihydroxy-6-methyloxan-2-yl]oxy-2,3,4,6,7,8,9,11,12,15,16,17-dodecahydro-1H-cyclopenta[a]phenanthren-17-yl]-2H-furan-5-one
  • Molecular Formula: C29H44O12
  • CAS Registry Number: 630-60-4
  • InChI: InChI=1S/C29H44O12/c1-13-22(34)23(35)24(36)25(40-13)41-15-8-19(32)28(12-30)21-17(3-5-27(28,37)9-15)29(38)6-4-16(14-7-20(33)39-11-14)26(29,2)10-18(21)31/h7,13,15-19,21-25,30-32,34-38H,3-6,8-12H2,1-2H3/t13-,15-,16+,17?,18+,19+,21?,22-,23+,24+,25-,26+,27-,28
  • InChI Key: LPMXVESGRSUGHW-HBYQJFLCSA-N

@ ChemSpider@ NIST@ PubChem

Citations 2

"Native Peroxyoxalate Chemiluminescence From The Reaction Of Bis-(2,4-dinitrophenyl) Oxalate And Hydrogen Peroxide Perturbed By Non-fluorophores"
Anal. Chim. Acta 1987 Volume 196, Issue 1 Pages 305-310
A. C. Capomacchia, R. N. Jennings, S. M. Hemingway, P. D'Souza, W. Prapaitrakul and A. Gingle

Abstract: The injection of a non-fluorophore enhanced the background chemiluminescence (at ~400 nm) from solution of bis-(2,4-dinitrophenyl) oxalate and H2O2 in CHCl3, ethyl acetate, butyl acetate or acetonitrile. These effects were studied in detail by use of a flow injection system. An eight-fold intensity enhancement was obtained with a 20 µL injection of 0.1 µM-ouabain or 1 µM-urea and the response was quantitative.
Chemiluminescence Indirect Sensitivity

"Spectrophotometric Determination Of Cardiac Glycosides By Flow Injection Analysis"
Anal. Chim. Acta 1992 Volume 269, Issue 2 Pages 199-203
P. Solich*, V. Sedliaková and R. Karlíek

Abstract: An optimized flow injection analysis method was described for the determination of lanatoside A, B and C, digoxin, digitoxin, acetyldigitoxin and ouabain, based on their reaction with picric acid in alkaline media and spectrophotometric detection at 486 nm. The flow injection manifold (diagram given) consisted of a FIA 20 Analyser linked to a Zeiss Spekol 10 photometer; the flow rate was 0.6 mL min-1 through the PTFE reaction coil (200 cm) with a sample volume of 100 µL. The calibration graph was rectilinear for 0.025 to 0.5 g L-1 for the cited glycosides (except ouabain) and from 0.01 to 0.2 g L-1 for ouabain; coefficient of variation (n = 6) were 0.6 to 2.2%. Sample throughput was 60 h-1. An optimized flow injection method for the determination of various cardiac glycosides (lanatoside A, B and C, digoxin, digitoxin, acetyldigitoxin, and ouabain) was based on their reaction with picric acid in alkaline media with spectrophotometric detection at 486 nm. The calibration graph was linear for 0.025-0.5 g L-1 cardiac glycosides (except ouabain) and 0.01-0.2 g L-1 ouabain, with relative standard deviation between 0.62 and 2.16% and a sample throughput of 60 h-1. This method was utilized for the determination of digoxin in tablets and lanatoside C, and ouabain in injections.
Pharmaceutical Pharmaceutical Spectrophotometry Optimization