Catechol, derivatives
Citations 1
"The Application Of Various Immobilized Crown Ether Platinum-modified Electrodes As Potentiometric And Amperometric Detectors For Flow Injection Analyses Of Catechol And Catecholamines"
Electroanalysis
1995 Volume 7, Issue 5 Pages 420-424
Suzanne K. Lunstord, Yi-Long Ma, Ahmed Galal, Cynthia Striley, Hans Zimmer, Harry B. Mark Jr.
Abstract:
The crown ethers were polymerized onto a 2 mm diameter Pt disc electrode. The monomer solution comprised 0.025 M crown ether and 0.20 M tetrabutylammoniumtetrafluoriborate as supporting electrolyte in acetonitrile. Amperometric measurements were performed with a BAS model MF-1021 flow cell. Static potentiometric and potentiometric FIA measurements were performed with the polymer-modified electrode PTFE block incorporated into a standard BAS thin-layer flow cell with a Ag/AgCl electrode as second electrode. Measurements were performed with an Orion model 601A ionanalyzer. The potentiometric FIA response of all the crown ethers was linear over the range 10 mM to 10 µM. The lowest detection limits were 0.5 µmM for the potentiometric FIA with minimum interference from ascorbic acid, uric acid and acetaminophen. Detection limits for amperometric FIA was 5 µmM but there was significant interference from ascorbic acid, uric acid and acetaminophen.
Amperometry
Electrode
Electrode
Potentiometry
Crown ether
Complexation
Interferences